Working Principle of Rapi Scan 527/528
As son as an
object enter the inspection chamber and cut off the beam of infrared rays made
by OSM (Optical Sensor Module) it is
suddenly transmitted to System Control
Board and System Control Board
Command the X-Ray controller to turn the X-Rays on.
When X-Ray
are turned on, it starts scanning the object some x-rays pass through the
object , some are absorbed and some are scattered in different directions
according to the density of object. After passing through the object , X-Rays
are detected by LXDA (Liner x-Ray
Detector Array/ Diode) board which converts these X-Rays signal into
digital signal and send these signal to Main Computer Memory where after normalization and processing with
the help of SVGA (Super Video Graphic
Adopter) these signal are converted into video signals and sent to VDU (Video Display Unit) as an image.
st Image Processor). HIP Board these converted these digital signals into
video signals and sent to VDU (Video
Display Unit) as an image.urity measures to protect Departure Lounge/Aircraft Cabin. All Articles which can be used to commit an act of unlawful interference are prohibited to carry beyond this point.